Engineering Project
Hilton Rialto Place — MEP Systems Assessment
- Melbourne, Florida
- 146,000 SF
- Commercial / Hospitality
- Specialized Engineering

Project Overview
Hilton Rialto Place in Melbourne, Florida is a 146,000-square-foot hotel with 237 guestrooms, meeting rooms, and ancillary spaces. BEED Engineering provided an MEP systems assessment of the existing building.
This assignment was not a design of a new hotel. It was an evaluation of the mechanical, electrical, and plumbing systems already in service — central plant, guestroom terminals, kitchen and laundry equipment, and electrical distribution — so the owner could see what was there and what needed further testing.
The Challenge
A full-service hotel concentrates almost every MEP system type in one building: water-cooled chillers and cooling towers, boilers, air-handling units, fan coils, domestic water boosting, fire pumps, laundry, walk-in coolers, dishwashing, and a main electrical service. Drawings are often incomplete. Operating staff know symptoms; they may not have a current inventory of equipment condition.
The assessment had to:
- Identify the installed MEP systems across 146,000 square feet and 237 guestrooms
- Cover mechanical plant, hydronic distribution, HVAC terminals, plumbing, fire protection pumps, and electrical gear
- Flag electrical equipment that needed a more detailed test than a visual survey
For a complete assessment of electrical systems, BEED recommended infrared scanning of electrical cabinets, breaker panels, fuses, bolted connections, and switchgear.
BEED Engineering's Scope
BEED provided an MEP systems assessment of Hilton Rialto Place. The work was an evaluation of existing systems, not construction-document design for a new building.
Engineering Solutions
The assessment documented the hotel’s installed systems, including gas-fired boilers, chilled and hot water piping, domestic water booster pumps, water-cooled chillers, cooling towers, air-handling units, fan coils, variable frequency drives, packaged DX systems, fire pumps, commercial laundry equipment, walk-in coolers, dishwashing machines, the main service switchboard, motor control centers, electrical panels, lighting control, and the voice evacuation system.
That inventory is the starting point for capital planning. Infrared scanning of electrical gear, which BEED recommended, is the next step when a visual MEP assessment is not enough to judge connection and overheating risk in a 237-room hotel.
Related BEED Services
Service
Facility Assessments
Condition assessments and capital planning support for existing mechanical, electrical, and plumbing systems.
Service
Mechanical Engineering
HVAC, chilled water, central plants, ventilation, humidity control, and building automation for commercial and institutional buildings.
Service
Electrical Engineering
Power distribution, lighting, generators, fire alarm, and low-voltage systems for new construction and renovations.
Service
Chilled Water Systems
Chiller plants, pumping, air-handling equipment, and controls for larger commercial and institutional facilities.
Related Locations
Related Resources
What Is a Facility Assessment?
A facility assessment is an engineering review of existing mechanical, electrical, and plumbing systems to document condition, remaining life, and recommended work.
What Is a Chilled Water System?
A chilled water system uses a chiller to cool water that is pumped to air-handling units and other coils, then returned to the plant to be cooled again.
What Is HVAC Engineering?
HVAC engineering is the design of heating, ventilating, and air-conditioning systems that control temperature, humidity, ventilation, and indoor air quality.
What Is Electrical Power Distribution?
Electrical power distribution is the path from the utility service through switchgear and panels to the building’s lights, receptacles, and equipment.
How Do You Control Humidity in a Commercial Building?
Commercial humidity control depends on dehumidification at the cooling coil, proper outdoor-air treatment, runtime, and controls—not just a lower thermostat setpoint.
Related Projects
BEED Engineering
Aerospace
SpaceX PPF
Cape Canaveral, Florida · Mechanical Engineering
Aerospace
SpaceX PPF
East SMAG Cleanroom HVAC Study
Cape Canaveral, Florida
Mechanical Engineering
A mechanical study of the existing HVAC system at the SpaceX Payload Processing Facility East SMAG in Cape Canaveral, Florida, to determine the upgrades required for ISO 8 cleanroom conditions in a 6,400-square-foot, 140-foot high bay.
View Project →
Education
Meadowlane Intermediate School
Central Energy Plant
West Melbourne, Florida
Mechanical + Plumbing Engineering
Mechanical and plumbing engineering and project administration for a 116,700-square-foot school and water-cooled central energy plant in West Melbourne, Florida.
View Project →
Healthcare
Apollo Surgery Center
Surgical Facility Expansion
West Melbourne, Florida
Mechanical + Plumbing + Fire Protection
Mechanical, plumbing, and fire protection engineering for an 8,000-square-foot expansion of a surgical facility in West Melbourne, Florida.
View Project →Local Presence
BEED Engineering — Based in Palm Bay, Serving Central Florida
BEED Engineering is an MBE professional consulting engineering firm providing building mechanical, electrical, and plumbing (MEP) engineering design and consulting services. We are based in Palm Bay, Central Florida. BEED Engineering is a firm you can trust to get the job done.
Next Project
Have a Similar Engineering Project?
Talk with BEED Engineering about your next facility assessment or mechanical, electrical, and plumbing project.